![]() Secondly, I wanted Alpha display keypads with customizable text. This rules out most of the Radionics line, which require a separate handheld programmer. My first requirement was for a system that is keypad programmable. After many years in the alarm business, I had seen many panels come and go, while others remained popular. In addition, relays can be activated remotely with the addition of an Escort module (see below).Īt the time I installed a DSC Power 832 in my own home, I had my choice of any panel on the market. The user can initiate relay outputs through button presses at a system keypad. ![]() Status outputs like system trouble and armed condition are automatically issued by the panel. The two PGM outputs can be programmed for many other functions, including relay activation, system status outputs, etc. The PGM out provides switched power for resetting the 4-wire smokes, while one of the standard zone inputs is programmed for the fire alarm function. ![]() Using one of the two PGM Outputs allows the DSC 832 to work with 4-wire smoke detectors. The connections are compatible with several different 2-wire smoke alarm models, and provide both switched power and alarm functions on the same two terminals. The fire zone is optimized for 2-wire smoke detectors using the PGM2 terminal.